摘要: Double parallel-plate avalanche counters (DPPACs), each comprising two PPACs with delay-line readout for two-dimensional position determination, have been developed at Institute of Modern Physics, Chinese Academy of Sciences. The detector was tested with a standard α source, achieving a position resolution of about 0.4 mm. Each PPAC measures particle hit positions in two dimensions, with the dual configuration enhancing overall detection efficiency. Two DPPACs were deployed in a month-long experimental campaign at the Radioactive Ion Beam Line in Lanzhou (RIBLL1) with secondary beams of 10C, 10Be, 11C and 16C at typical intensities of 1.2 -- 1.5 × 105 Hz, yielding a stable single DPPAC-detection efficiency >90% and a typical in-beam position resolution ≈ 0.54 mm.