您当前的位置: > 详细浏览

Study of Photon Detection Efficiency and Position Resolution of BESIII Electromagnetic Calorimeter 后印本

请选择邀稿期刊:
摘要: We study the photon detection efficiency and position resolution of the electromagnetic calorimeter (EMC) of the BESIII experiment. The control sample of the initial-state-radiation (ISR) process of e+e−→γμ+μ− is used at J/ψ and ψ(3770) resonances for the EMC calibration and photon detection efficiency study. Photon detection efficiency is defined as the predicted photon, obtained by performing a kinematic fit with two muon tracks, matched with real photons in the EMC. The spatial resolution of the EMC is defined as the separation in polar (θ) and azimuthal (ϕ) angles between charged track and associated cluster centroid on the front face of the EMC crystals.

版本历史

[V1] 2016-09-13 08:48:07 ChinaXiv:201609.00922V1 下载全文
点击下载全文
预览
同行评议状态
待评议
许可声明
metrics指标
  •  点击量2440
  •  下载量1063
评论
分享
  • 运营单位: 中国科学院文献情报中心
  • 邮箱: eprint@mail.las.ac.cn
  • 地址:北京中关村北四环西路33号
招募志愿者 许可声明 法律声明

京ICP备05002861号-25 | 京公网安备11010802041489号