摘要: High-purity perfluorohexane is a key liquid-radiator candidate for Ring Imaging Cherenkov detectors, provided that sufficient optical transparency can be achieved and maintained in the vacuum-ultraviolet (VUV) region. In practice, commercially available samples often exhibit strong VUV absorption due to dissolved contaminants, including water, oxygen, and other residual impurities. In this work, we develop high-purity perfluorohexane through dedicated material preparation together with an efficient circulation purification scheme, and we characterize its optical performance with a custom VUV transmission measurement setup. With continuous purification, the VUV transparency improves substantially; the resulting samples exceed the performance of previously reported commercial products and satisfy the requirements for high-performance liquid Cherenkov radiators. These results provide a practical, scalable route to mitigate the material bottleneck in liquid-radiator RICH detectors and support future detector developments.
-
来自:
Zhang, Dr. Huibin
-
分类:
物理学
>>
核物理学
-
备注:
已向《Nuclear Science and Techniques》投稿
-
引用:
ChinaXiv:202604.00310
(或此版本
ChinaXiv:202604.00310V1)
DOI:10.12074/202604.00310
CSTR:32003.36.ChinaXiv.202604.00310
-
科创链TXID:
056ee112-361b-414f-a837-5c29bff9e7ab
- 推荐引用方式:
Zhang, Dr. Huibin,刘, Prof. 倩,Huang, Dr. Qingyuan,Chen, Dr. Shi,Zheng, Prof. Yangheng,Huang, Dr. Wenqian,Wang, Dr. Anqi,Liang, Dr. Kunyu,Zhang, Dr. Zhiyong,Liu, Dr. Jianbei.Purification and VUV Transmission Characterization of High-Purity Perfluorohexane for Liquid Cherenkov Radiators.null.[DOI:10.12074/202604.00310]