摘要: The efficiency of converting generator microwave power into accelerated beam power is an important parameter for traveling- and standing-wave linear electron accelerators. Current electron accelerators with a standing-wave accelerating structure operate in a mode where, during beam acceleration, all the generator microwave power, without reflections, is coupled into the accelerating structure. This is the "critical coupling" mode between the structure and the microwave power supply line. It seems obvious to the developers that this mode achieves maximum efficiency. In this study, we demonstrate through calculations and experiments that the "critical coupling" mode is not optimal for achieving maximum efficiency. From the obtained relationships determining the operating modes of the accelerating structure under beam current loading, it follows that, as the current increases, the "critical coupling" mode between the structure and the supply line is initially achieved, followed by the maximum efficiency mode. Calculations, estimates, and experiments show that in an operating accelerator with a standing-wave accelerating structure, during the transition from the "critical coupling" mode to the maximum efficiency mode, by increasing the beam current, it is possible to significantly - by 1.5 to 2 times - increase the efficiency of converting the microwave generator power into beam power.